VF series elevator towing motor

Brief Introduction
  VF series elevators towing motor is self-cooling, frequency conversion, speed adjusting, three phase, asynchronous motor of protective type. It has characteristics of big starting torque and low starting current at low frequency and voltage. It is mainly used as motive power for elevators.

   

Working Conditions
  rated frequency and frequency are according to customers' requirements;
  Tempertature of coolant medium is not above 40≧;
  Elevation is not above 1000m;
  It is put at the dry and dust free place;
  Insulation grade is B;

Basic type
  Protection grade is IP20;
  Cooling way is IC01;
  Installation type is IMB9;
  The motor is in S2-30 min short-term working system.

Functonal parameters
Type pole
no.
rated
power
(kw)
rated
voltage
(V)
rated
frequency
(Hz)
conn-ection rated
current
(A)
effic-iency
(%)
power
factor
(cosφ)
starting torque starting torque max torque rotation
speed
(r/min)
temper-ature
rising
(K)
vibr-ation
um
noise
(LP)
dB
(A)

VF160L-4S

4

11

170

60

Y

47.0

91.2

0.878

2.2

5.7

3.2

1760

80

10

70

VF160L-4S1

4

15

170

60

Y

62.9

89.8

0.907

1.5

4.9

2.2

1745

80

10

70

VF160L-4S2

4

15

150

50

Y

72.4

87.9

0.908

1.4

4.3

2

1435

80

10

70

VF160L-4S3

4

13

130

43

Y

73.6

86.3

0.910

1.4

4.1

1.9

1225

80

10

70

VF160L-4C

4

15

330

50

Y

32.5

90.5

0.893

2.0

5.7

2.7

1456

80

10

70

VF160L-4S4

4

11

380

50

Y

20.9

89.7

0.889

2.1

6.2

2.9

1459

80

10

70

VF160L-4C1

4

15

380

50

Y

28.4

90.3

0.888

2.4

6.8

3.2

1412

80

10

70

VF180L1-6C

6

11

330

50

Y

26.2

89.5

0.822

2.2

5.7

2.8

976

80

10

70

VF180L2-4C

4

18.5

330

50

Y

40.8

92.4

0.859

2.5

6.5

3.7

1470

80

10

70

VF180L1-6C1

6

11

380

50

Y

22.9

89.4

0.813

2.7

6.7

3.2

980

80

10

70

VF180L2-4C2

4

18.5

380

50

Y

34.2

91.0

0.899

2.0

6.2

2.9

1465

80

10

70


COPYRIGHT WUXI TIANBAO ELECTRICAL MACHINERY CO.,LTD.  TEL:0086-0510-83880261、83898662  Huashang.com